Garage Gym Humidity Calculator
Water condenses on steel that is at or below the dew point of the air around it. Garage air at 68 °F and 70 percent relative humidity has a dew point of 57.9 °F, so a bar still at 50 °F will collect water and a bar at 65 °F will not. The Canadian Conservation Institute says all iron rusts when relative humidity is over about 65 percent.
Enter the air temperature and relative humidity in your garage, and the temperature of the steel if you know it. The calculator gives the dew point of that air, says whether a bar or plate at that temperature is at or below it, shows what the air's humidity becomes at the steel, and gives the humidity at which the dew point would reach the steel. The formula and its coefficients come from a NOAA report we read on 21 Nov 2026. The words attached to each result are ours. This page does not predict rust.
Read the air temperature and humidity off a hygrometer in the garage. The steel can be a different temperature from the air. To test a cold morning, enter the temperature the bar sat at overnight. Leave the box empty and the calculator takes the steel to be at the air temperature and tells you how much colder it would have to be.
Condensation likely
Air at 68 °F and 70 percent relative humidity has a dew point of 57.9 °F. Steel at 50 °F is 7.9 °F below it, so water will condense on the steel.
| Reading | Value |
|---|---|
| Air | 68 °F, 70 percent relative humidity |
| Dew point of that air | 57.9 °F |
| Steel | 50 °F |
| Steel compared with the dew point | 7.9 °F below the dew point |
| Relative humidity of that air at the steel's temperature | 100 percent, saturated. The formula gives 133.2, and the part over 100 is the water that condenses |
| Relative humidity at which the dew point reaches the steel, at this air temperature | 52.5 percent |
At the steel this air is saturated, at 100 percent relative humidity. The Canadian Conservation Institute's note on storing metals says "All iron rusts when the RH is over about 65%." The same institute's page on incorrect relative humidity says "In general for metals, the lower the RH the better, above 75% RH all corrosion speeds up a lot." The humidity at the steel is above both figures. Both are that institute's figures for objects in museum storage, not a rust prediction from us. The National Weather Service's published formula puts the same dew point at 57.86 °F, against 57.85 °F here.
The dew point and the percentages come from the sourced formula. The labels, such as "condensation likely", are our words for what the numbers say. Nothing here predicts rust. See the limits.
Worked examples: dew point on a cold bar
A bar colder than the air. Take garage air at 68 °F and 70 percent relative humidity, and a bar that is still at 50 °F. Here is the arithmetic, step by step.
- Convert to Celsius. Air: (68 - 32) x 5 / 9 = 20 °C. Steel: (50 - 32) x 5 / 9 = 10 °C.
- Saturation vapour pressure at the air temperature. 6.1094 x e^(17.625 x 20 / (243.04 + 20)) = 6.1094 x e^1.3401 = 23.3344 hPa.
- The air's vapour pressure. 70 percent of that: 0.7 x 23.3344 = 16.3341 hPa.
- Dew point. The temperature at which the formula gives 16.3341 hPa. With g = ln(16.3341 / 6.1094) = 0.9834, the dew point is 243.04 x 0.9834 / (17.625 - 0.9834) = 14.3623 °C, and 14.3623 x 9 / 5 + 32 = 57.852 °F.
- Steel against the dew point. 50 - 57.852 = -7.852 °F, so the steel is 7.9 °F below the dew point.
- Relative humidity of that air at the steel. Saturation at the steel's temperature: 6.1094 x e^(17.625 x 10 / (243.04 + 10)) = 6.1094 x e^0.6965 = 12.2602 hPa. Then 16.3341 / 12.2602 x 100 = 133.2, which is over 100, so the air is saturated at the steel.
- The reverse. The relative humidity at which this air's dew point reaches the steel: 12.2602 / 23.3344 x 100 = 52.5 percent.
Air at 68 °F and 70 percent relative humidity has a dew point of 57.9 °F. Steel at 50 °F is 7.9 °F below it, so water will condense on the steel. The air is at 70 percent, well over the 52.5 percent at which its dew point reaches a bar that cold.
The same air, a warmer bar. Let the bar warm to 65 °F and the answer changes. Air at 68 °F and 70 percent relative humidity has a dew point of 57.9 °F. Steel at 65 °F is 7.1 °F above it, so this air will not condense on the steel. At the bar that air reads 77.7 percent relative humidity, and it would take 90.1 percent in the room to bring the dew point up to the bar.
| Reading | Value |
|---|---|
| Air | 68 °F, 70 percent relative humidity |
| Dew point of that air | 57.9 °F |
| Steel | 65 °F |
| Steel compared with the dew point | 7.1 °F above the dew point |
| Relative humidity of that air at the steel's temperature | 77.7 percent |
| Relative humidity at which the dew point reaches the steel, at this air temperature | 90.1 percent |
No steel temperature. Leave the steel box empty and the calculator works from the air alone. Air at 68 °F and 70 percent relative humidity has a dew point of 57.9 °F. Steel at the air's own temperature is 10.1 °F above the dew point, so this air will not condense on it. Water will condense on any steel that is at 57.9 °F or colder. The gap between the air temperature and the dew point, 10.1 °F here, is what the National Weather Service's glossary calls the dew point depression: "The difference in degrees between the air temperature and the dew point."
Air at 100 percent humidity. When the air is saturated, the dew point is the air temperature itself, and anything at that temperature or colder collects water. Air at 50 °F and 100 percent relative humidity has a dew point of 50 °F. Steel at 50 °F is at the dew point, so water will condense on the steel.
Drier air. Keep the air at 68 °F, drop the humidity to 45 percent and put the steel at 60 °F. Air at 68 °F and 45 percent relative humidity has a dew point of 45.9 °F. Steel at 60 °F is 14.1 °F above it, so this air will not condense on the steel. At the steel that air reads 59.5 percent relative humidity.
Steel warmer than the air. Steel that sat in a warm spot can be warmer than damp air that has just come in. With air at 60 °F and 90 percent and steel at 70 °F: Air at 60 °F and 90 percent relative humidity has a dew point of 57.1 °F. Steel at 70 °F is 12.9 °F above it, so this air will not condense on the steel. The same air warmed to the steel's temperature reads 63.5 percent, and no humidity up to 100 percent brings the dew point up to steel that is warmer than the air.
In Celsius. Switch to Celsius and enter the readings as they are. For air at 18 °C and 75 percent with steel at 12 °C:
- Saturation vapour pressure at the air temperature. 6.1094 x e^(17.625 x 18 / (243.04 + 18)) = 6.1094 x e^1.2153 = 20.5973 hPa.
- The air's vapour pressure. 75 percent of that: 0.75 x 20.5973 = 15.448 hPa.
- Dew point. The temperature at which the formula gives 15.448 hPa. With g = ln(15.448 / 6.1094) = 0.9276, the dew point is 243.04 x 0.9276 / (17.625 - 0.9276) = 13.5025 °C.
- Steel against the dew point. 12 - 13.5025 = -1.5025 °C, so the steel is 1.5 °C below the dew point.
- Relative humidity of that air at the steel. Saturation at the steel's temperature: 6.1094 x e^(17.625 x 12 / (243.04 + 12)) = 6.1094 x e^0.8293 = 14.0007 hPa. Then 15.448 / 14.0007 x 100 = 110.3, which is over 100, so the air is saturated at the steel.
- The reverse. The relative humidity at which this air's dew point reaches the steel: 14.0007 / 20.5973 x 100 = 68 percent.
Air at 18 °C and 75 percent relative humidity has a dew point of 13.5 °C. Steel at 12 °C is 1.5 °C below it, so water will condense on the steel.
| Reading | Value |
|---|---|
| Air | 18 °C, 75 percent relative humidity |
| Dew point of that air | 13.5 °C |
| Steel | 12 °C |
| Steel compared with the dew point | 1.5 °C below the dew point |
| Relative humidity of that air at the steel's temperature | 100 percent, saturated. The formula gives 110.3, and the part over 100 is the water that condenses |
| Relative humidity at which the dew point reaches the steel, at this air temperature | 68 percent |
Below freezing. The report gives its formula for water down to minus 40 °C, so the calculator still works in a freezing garage. For air at 30 °F and 85 percent with steel at 20 °F: Air at 30 °F and 85 percent relative humidity has a dew point of 26 °F. Steel at 20 °F is 6 °F below it, so water will condense on the steel. The steel is at or below freezing, so the water can arrive as frost. That figure is the dew point over water. The National Weather Service's glossary defines the frost point as "Dew point below freezing." The report has a separate formula for saturation over ice, which this calculator does not apply to your readings, so it prints no frost point.
Freezing steel above the dew point. Here the calculator gives no all clear. For air at 20 °F and 80 percent with steel at 16 °F: Air at 20 °F and 80 percent relative humidity has a dew point of 14.8 °F. Steel at 16 °F is 1.2 °F above it, so no dew is expected from this air. The steel is at or below freezing, where frost can form on steel that is still above this dew point, and this calculator does not check for frost. The label it shows is "No dew expected. Frost is not checked". Worked for this one reading with the report's ice formula, that air against that steel comes to 2.9731 / 2.865 x 100 = 103.8 percent of saturation over ice, which is over 100 although the steel is above the dew point. See the limits.
Dew point chart for a garage
Each row is an air temperature and each column a relative humidity. The cell is the dew point of that air. Steel at that temperature or colder collects water from it. Where a cell is below freezing it is still the dew point over water, and frost can start on steel warmer than the cell (see the limits). The rows and columns are our choice. Every cell comes from the same formula as the calculator.
| Air temperature | 30% | 40% | 50% | 60% | 70% | 80% | 90% |
|---|---|---|---|---|---|---|---|
| 40 °F | 11 | 17.6 | 22.8 | 27.2 | 31 | 34.3 | 37.3 |
| 50 °F | 19.8 | 26.6 | 32.1 | 36.7 | 40.6 | 44.1 | 47.2 |
| 60 °F | 28.5 | 35.6 | 41.3 | 46.1 | 50.2 | 53.8 | 57.1 |
| 70 °F | 37.1 | 44.6 | 50.5 | 55.5 | 59.8 | 63.5 | 66.9 |
| 80 °F | 45.8 | 53.5 | 59.7 | 64.9 | 69.3 | 73.3 | 76.8 |
| 90 °F | 54.4 | 62.4 | 68.9 | 74.3 | 78.9 | 83 | 86.7 |
| 100 °F | 63 | 71.4 | 78 | 83.6 | 88.5 | 92.7 | 96.5 |
| Air temperature | 30% | 40% | 50% | 60% | 70% | 80% | 90% |
|---|---|---|---|---|---|---|---|
| 5 °C | -11.2 | -7.5 | -4.6 | -2.1 | 0 | 1.8 | 3.5 |
| 10 °C | -6.8 | -3 | 0 | 2.6 | 4.8 | 6.7 | 8.4 |
| 15 °C | -2.4 | 1.5 | 4.7 | 7.3 | 9.6 | 11.6 | 13.4 |
| 20 °C | 1.9 | 6 | 9.3 | 12 | 14.4 | 16.4 | 18.3 |
| 25 °C | 6.2 | 10.5 | 13.9 | 16.7 | 19.1 | 21.3 | 23.2 |
| 30 °C | 10.5 | 14.9 | 18.4 | 21.4 | 23.9 | 26.2 | 28.2 |
| 35 °C | 14.8 | 19.4 | 23 | 26.1 | 28.7 | 31 | 33.1 |
The next two tables turn the question round. Pick how much colder than the air the steel is, and the cell is the relative humidity at which water starts to condense on it. In 70 °F air, steel 10 °F colder starts to collect water at about 71 percent, and steel 20 °F colder at about 49 percent.
| Air temperature | Steel 5 °F colder | Steel 10 °F colder | Steel 15 °F colder | Steel 20 °F colder | Steel 25 °F colder |
|---|---|---|---|---|---|
| 40 °F | 82% | 67% | 55% | 44% | 36% |
| 50 °F | 83% | 68% | 56% | 46% | 37% |
| 60 °F | 84% | 70% | 58% | 48% | 39% |
| 70 °F | 84% | 71% | 59% | 49% | 41% |
| 80 °F | 85% | 72% | 60% | 51% | 42% |
| 90 °F | 85% | 73% | 62% | 52% | 44% |
| 100 °F | 86% | 74% | 63% | 53% | 45% |
| Air temperature | Steel 3 °C colder | Steel 6 °C colder | Steel 9 °C colder | Steel 12 °C colder | Steel 15 °C colder |
|---|---|---|---|---|---|
| 5 °C | 81% | 65% | 52% | 42% | 33% |
| 10 °C | 82% | 66% | 54% | 43% | 34% |
| 15 °C | 82% | 67% | 55% | 45% | 36% |
| 20 °C | 83% | 68% | 56% | 46% | 37% |
| 25 °C | 83% | 69% | 57% | 47% | 39% |
| 30 °C | 84% | 70% | 59% | 49% | 40% |
| 35 °C | 85% | 71% | 60% | 50% | 42% |
How the calculator works
The formula is sourced. The steps around it are the National Weather Service's. A few choices are ours, and they are listed at the end.
- Saturation vapour pressure. This is the vapour pressure of air that is saturated at a given temperature. The calculator uses equation 25 of the report "Improved Magnus' form approximation of saturation vapor pressure", from NOAA's National Climatic Data Center: 6.1094 x e^(17.625 x t / (243.04 + t)), with t in °C and the answer in hPa. The report recommends it for minus 40 °C to 50 °C and puts its maximum relative error under 0.384 percent against the three reference formulations it names.
- The air's vapour pressure. The National Weather Service's formula sheet gives relative humidity as the vapour pressure over the saturation vapour pressure, times 100. So the air's vapour pressure is its relative humidity, as a fraction, times the saturation figure from step 1.
- Dew point. The same sheet writes the vapour pressure as the saturation formula with the dew point in place of the temperature. The dew point is therefore the temperature at which step 1's formula gives the air's vapour pressure. Solving the formula for that temperature is algebra, and the worked examples show it.
- Steel against the dew point. The steel's temperature minus the dew point. When that difference is zero or negative, the steel is at or below the dew point and water will condense on it.
- Humidity at the steel. The air's vapour pressure over the saturation vapour pressure at the steel's temperature, times 100. This is the relative humidity of that same air once it is cooled, or warmed, to the steel's temperature. Over 100 means the air is saturated there.
- The reverse. The saturation vapour pressure at the steel's temperature over the saturation vapour pressure at the air temperature, times 100. That is the room humidity at which the dew point reaches the steel.
- Fahrenheit. Readings in °F are converted with the National Weather Service's formula, 5/9 x (°F - 32), and converted back for the answer.
Two sourced forms differ, and we picked one. The National Weather Service's El Paso office publishes the form its own online calculator uses: 6.11 x 10^(7.5 x T / (237.3 + T)). That sheet states no range and no accuracy. The NOAA report's coefficients come with both, so the calculator uses the report's form. The two agree closely. For the first example above, the National Weather Service's form puts the dew point at 57.86 °F against 57.85 °F here, and the line under the results table prints that comparison for your own numbers.
A check against a conservation institute's examples. The Canadian Conservation Institute's page on relative humidity says "The dewpoint for air at 20°C and 50% RH is near 10°C." The formula gives 9.3 °C. The same page says "Air at 50% RH, if cooled by 10°C, e.g., from 25°C to 15°C, will now be at 100% RH." By the formula that air is at 92.9 percent at 15 °C and reaches saturation at 13.9 °C, after 11.1 °C of cooling, a little more than the institute's round 10. The institute's next sentence is the reason this calculator exists: "Further cooling results in condensation on objects."
What is ours. Steel counts as "at" the dew point when the two agree to the tenth of a degree this page prints. The labels "condensation likely", "at the dew point", "no condensation expected from this air" and "no dew expected", and the words "frost is not checked" beside a result, are ours. The last two appear when the steel is at or below freezing and above the dew point. The statement that frost can form there is our reading of the report's two formulas, set out under the limits. The calculator takes relative humidity from 1 to 100 percent, and the lower bound is ours. The rows and columns of the charts are our choice.
What the humidity at the steel says about rust
This calculator states condensation and gives no rust verdict. Beside the humidity at the steel it prints two figures from the Canadian Conservation Institute, a Government of Canada institute. They are that institute's figures, written for objects in museum storage.
Its note on storing metals says: "All iron rusts when the RH is over about 65%." The same note says: "Uncontaminated iron is stable at 50% RH, but iron contaminated with salts continues to corrode." Its page on incorrect relative humidity says: "In general for metals, the lower the RH the better, above 75% RH all corrosion speeds up a lot." That page gives the reason in two sentences: "Damp causes rapid corrosion of metals." and "The layer of water molecules that is always present on the surface of metals, grows rapidly above 75% RH." It adds that salt from hands takes up water from the air above 75 percent "and forms a very corrosive solution".
Why the humidity at the steel and not the humidity in the room: the institute's page says "Uneven temperature across a package leads to damp, even condensation, at the end that is consistently colder than most of the package." A cold bar in milder air is in the same position as that colder end. The room can read 70 percent while the air against the bar is saturated, as in the first example.
What is a good humidity level for a garage gym? We found no figure from a conservation or corrosion authority written for a gym. For a museum store the institute's note says "The RH should be between 35% and 55%, the range generally recommended for storing and displaying mixed collections." In its section on storing actively corroding metal it says of household dehumidifiers: "Domestic dehumidifiers are not as effective as silica gel dehumidifiers because they cannot reduce the RH below 40%, but they are better than no dehumidifier at all." A garage is not a museum store, and a plated or painted bar is not a bare iron artifact, so read those as the institute's targets for its own purpose. What the calculator can tell you for any target is how far the steel is from the dew point.
For the rust question itself, see will weights rust in a garage. If rust is already there, see how to remove rust from weights.
Limits
It does not predict rust. It says whether water will condense on steel at one temperature in air at one reading, and it quotes a conservation institute's humidity figures beside the result. The institute's own sentences show that humidity is not the whole story: it calls clean iron stable at 50 percent and says iron contaminated with salts continues to corrode. The calculator knows nothing about the finish or the surface of your steel.
It does not read a hygrometer. The answer is only as good as the readings you type. The report's own closing note applies: "the errors discussed in this paper are much less than observational errors in humidity values due to the hygrometers."
The steel's temperature is your number. The calculator does not estimate how cold a bar is or how fast it warms. The answer holds for the temperature you entered.
No sun, wind or wet floors. It takes one air reading for the whole garage. It does not allow for sun on the steel, moving air, a wet floor, or water that reaches the steel any other way.
Range and accuracy of the formula. The report gives its formula for minus 40 °C to 50 °C, which is minus 40 °F to 122 °F, and the calculator refuses air or steel temperatures outside that. Its stated maximum relative error is under 0.384 percent in vapour pressure. The calculator uses the formula for pure water vapour and leaves out the report's correction for air pressure. The report says neglecting that correction can put the saturation vapour pressure of moist air off by up to 0.596 percent with respect to water. Very dry, very cold air can have a dew point below the range, and then no dew point is given.
No frost point. Below freezing the calculator still prints the dew point over water. The report's equation 27 is a separate formula for saturation over ice, and the two differ. At minus 10 °C (14 °F) the report's formula for water gives 2.868 hPa and its formula for ice gives 2.597 hPa. Saturation over ice is the lower figure. So air whose dew point over water is minus 10 °C is at 110.4 percent of saturation over ice at that temperature, and the ice formula gives that same vapour pressure at minus 8.9 °C (16 °F), which is 1.1 °C (2 °F) warmer. Our reading of that: on steel at or below freezing, frost can begin while the steel is still above the dew point printed here, by about that much when the dew point is near minus 10 °C, by less nearer freezing and by more in colder air. The calculator does not work this out for your readings. When the steel is at or below freezing and above the dew point, it says that no dew is expected and that frost is not checked, and it gives no all clear.
"At the dew point" is a rounding rule. Steel within a twentieth of a degree of the dew point is shown as at it. When that happens and the formula's humidity at the steel prints just under 100 percent, the table says about 100 and gives the formula's own figure beside it. A reading typed to the nearest degree cannot settle a margin that small, so treat a small margin either way as uncertain.
Nothing about health. This page is about water on steel. It makes no statement about mould, air quality or anyone's health.
Short answers
What is a good humidity level for a garage gym?
We found no figure from a conservation or corrosion authority written for a gym. For iron in museum storage, the Canadian Conservation Institute says "All iron rusts when the RH is over about 65%" and that uncontaminated iron is stable at 50 percent. Its range for mixed museum collections is 35 to 55 percent. Whatever the room reads, steel at or below the dew point gets wet.
Will weights rust in a garage?
This calculator cannot say. It tells you whether water will condense on steel at a given temperature and what the air's humidity is at the steel. The Canadian Conservation Institute's figures for iron are the only rust figures on this page, and they were written for museum objects. Our guide on whether weights rust in a garage covers the rest.
How do I keep weights from rusting in a garage?
Two things show up in the numbers. Water condenses on steel at or below the dew point, so steel that stays above the dew point does not collect water from the air. And the Canadian Conservation Institute says that for metals "the lower the RH the better". Our guides on storing weight plates and cleaning a barbell cover the practical steps.
What is the dew point?
The National Weather Service's glossary calls it "the temperature to which air must be cooled in order to reach saturation", with air pressure and moisture content held constant. It adds: "A higher dew point indicates more moisture present in the air." Air at 68 °F and 70 percent relative humidity has a dew point of 57.9 °F.
Why does moisture form on weights in a garage gym?
Water condenses on steel that is at or below the dew point of the air around it. With garage air at 68 °F and 70 percent, the dew point is 57.9 °F, so a bar still at 50 °F is 7.9 °F below it and collects water. Enter your own readings to see how close your bar is.
At what humidity does condensation form on a barbell?
It depends on how much colder the steel is than the air. In 70 °F air, steel 10 °F colder starts to collect water at about 71 percent relative humidity, and steel 20 °F colder at about 49 percent. Steel at the air's own temperature stays dry until the air reaches 100 percent.
Does the humidity calculator work in Celsius?
Yes. Switch to Celsius and enter the readings as they are. Air at 18 °C and 75 percent has a dew point of 13.5 °C, so steel at 12 °C is below it. The formula itself works in Celsius, and Fahrenheit readings are converted first.
Does it give the frost point?
No. Below freezing it prints the dew point over water, which the source's formula covers down to minus 40 °C. The frost point over ice needs a separate formula that this calculator does not apply to your readings. On steel at or below freezing, frost can form while the steel is still above that dew point, so there the result says frost is not checked.
Next steps
If the numbers say your steel sits below the dew point on some mornings, the questions that follow are practical ones. Will weights rust in a garage takes the rust question itself. How to store weight plates covers racks, trees and keeping plates off the floor. How to clean a barbell covers brushing and oiling by finish, and how to remove rust from weights covers what to do once rust shows.
Sources
We opened each of these on the date shown and checked the figures on this page against them. Prices and listings change, so follow the links for the current figure. How we write and check guides is in our editorial policy.
- Improved Magnus' form approximation of saturation vapor pressure (technical report DOE/ER/61011-T6), NOAA National Climatic Data Center, via the US Department of Energy's Office of Scientific and Technical Information. Used for: The saturation vapour pressure formula the calculator uses, the report's equation 25 (the approximation it calls AEKR): 6.1094 x e^(17.625 t / (243.04 + t)), t in degrees Celsius, in hPa, recommended there for minus 40 C to 50 C with a maximum relative error under 0.384 percent against the three reference formulations it names; its equation 27 for saturation over ice, 6.1121 x e^(22.587 t / (273.86 + t)), used only for the comparison in the limits section; its figure of 0.596 percent for neglecting the correction for air pressure; 'the errors discussed in this paper are much less than observational errors in humidity values due to the hygrometers'. The full text is a scanned report linked from this record, which we read by eye. Checked .
- Vapor Pressure (formula sheet for the office's weather calculator), US National Weather Service, El Paso forecast office. Used for: Relative humidity as the vapour pressure over the saturated vapour pressure, times 100; the vapour pressure written as the saturation formula at the dew point; the office's own form, 6.11 x 10^(7.5 T / (237.3 + T)), in millibars or hPa, used for the comparison line. The sheet states no range and no accuracy. Checked .
- Wet-bulb Temperature and Dewpoint Temperature from Air Temperature and Relative Humidity, US National Weather Service, El Paso forecast office. Used for: The office's dew point formula, 237.3 x ln(es x rh / 611) / (7.5 x ln 10 - ln(es x rh / 611)), in degrees Celsius, printed beside our dew point as a check. Checked .
- Temperature Conversion, US National Weather Service, El Paso forecast office. Used for: Celsius from Fahrenheit as 5/9 x (Tf - 32), and Fahrenheit from Celsius as 9/5 x Tc + 32. Checked .
- Glossary: Dew Point, US National Weather Service. Used for: Dew point as 'the temperature to which air must be cooled in order to reach saturation (assuming air pressure and moisture content are constant)'; 'A higher dew point indicates more moisture present in the air.'; dew point depression as 'The difference in degrees between the air temperature and the dew point.'. Checked .
- Glossary: Frost Point, US National Weather Service. Used for: Frost point defined as 'Dew point below freezing.'. Checked .
- Glossary: Freeze, US National Weather Service. Used for: Freezing taken as 32 °F: 'A freeze is when the surface air temperature is expected to be 32°F or below', which the conversion above makes 0 °C. Checked .
- Storage of Metals, Canadian Conservation Institute (CCI) Notes 9/2, Canadian Conservation Institute, Government of Canada. Used for: 'All iron rusts when the RH is over about 65%.'; 'Uncontaminated iron is stable at 50% RH, but iron contaminated with salts continues to corrode.'; 'The RH should be between 35% and 55%, the range generally recommended for storing and displaying mixed collections.'; 'Domestic dehumidifiers are not as effective as silica gel dehumidifiers because they cannot reduce the RH below 40%, but they are better than no dehumidifier at all.' (from its section on storing actively corroding metal). Written for museum storage. Checked .
- Agent of Deterioration: Incorrect Relative Humidity, Canadian Conservation Institute, Government of Canada. Used for: 'In general for metals, the lower the RH the better, above 75% RH all corrosion speeds up a lot.'; 'Damp causes rapid corrosion of metals.'; 'The layer of water molecules that is always present on the surface of metals, grows rapidly above 75% RH.'; salt from hands deliquesces above 75% RH 'and forms a very corrosive solution'; 'Uneven temperature across a package leads to damp, even condensation, at the end that is consistently colder than most of the package.'; 'The dewpoint for air at 20°C and 50% RH is near 10°C.' and 'Air at 50% RH, if cooled by 10°C, e.g., from 25°C to 15°C, will now be at 100% RH. Further cooling results in condensation on objects.'. Checked .